# Voltage Drop Calculation: Formula, Examples and Cable Sizing

Learn how voltage drop is calculated for single-phase, three-phase and DC circuits, see worked examples, and use the result to size cables safely.

Voltage drop calculation compares the volts lost along a conductor with the supply voltage, using current, cable length and conductor resistance. The basic formula multiplies current by resistance and applies a factor for the circuit type: two for single-phase and about 1.73 for three-phase. The result, expressed as a percent voltage drop, tells you whether the chosen wire cross-section is large enough. 

- Voltage drop rises with current, cable length and conductor resistance, so a longer or thinner run loses more volts.
- Use the single-phase formula with a factor of two, and the three-phase formula with the square root of three, to account for the return path.
- Convert the drop to a percent of supply voltage and compare it with the limit the circuit needs to meet.
- Increase wire cross-section or shorten the run to reduce voltage drop, then recalculate before finalizing the cable size.
- Fire alarm and car audio circuits each need their own check because their supply and load behavior differ from mains wiring.
 

## What voltage drop calculation measures 

Voltage drop calculation measures how many volts a conductor consumes as current flows through its resistance. Wire is not a perfect path, so part of the supply voltage is lost between the source and the load. The loss appears as heat in the cable and as lower voltage at the equipment. 

Resistance per length is the key property, expressed in ohms per meter or ohms per foot. A thin conductor has more resistance per length than a thick one, so it drops more volts for the same current. Cable length matters because resistance accumulates along the whole run, including the return leg. 

The calculation uses cable length and current together with conductor resistance. Doubling the current or the length doubles the voltage drop when resistance stays the same. That relationship makes voltage drop a practical check on whether a wire cross-section suits the job. 

## The voltage drop formula explained 

The voltage drop formula is voltage drop equals current times resistance times a circuit factor. Current is in amperes and resistance is the total conductor resistance over the run in ohms. The circuit factor adjusts the result for the number of live conductors carrying current. 

For a direct current circuit, the formula is simply current times the total loop resistance. Direct current has no reactance, so resistance per length alone describes the drop. DC cable voltage drop uses the same numbers as the single-phase case when reactance is ignored. 

Alternating current circuits also have reactance, which adds a small amount to the impedance. For small cables and modest currents, resistance dominates and the simple formula gives a usable estimate. Larger cables and long runs may need the full impedance value from the cable data. 

## Single-phase voltage drop calculation 

Single-phase voltage drop calculation uses a factor of two because current travels out and back along two conductors. The single-phase formula is voltage drop equals two times current times resistance per length times cable length. The return conductor carries the same current, so its resistance counts in full. 

A worked example makes the steps clear. Suppose a 20 ampere load sits 30 meters from the supply on a conductor with 0.0055 ohms per meter. Two times 20 amperes times 0.0055 ohms per meter times 30 meters gives about 6.6 volts of drop. On a 230 volt supply that is roughly 2.9 percent voltage drop. 

Converting the result to percent requires dividing the drop by the supply voltage and multiplying by one hundred. A drop that looks small in volts may still be large as a share of a low-voltage supply. Always state the percent voltage drop next to the volt figure when comparing options. 

## Three-phase voltage drop calculation 

Three-phase voltage drop calculation uses the square root of three, about 1.73, instead of the factor of two. The formula is voltage drop equals 1.73 times current times resistance per length times cable length. Balanced three-phase loads share the return path through the neutral or the other phases, which changes the factor. 

A three-phase example starts with line current, not phase current. Take 50 amperes on a 400 volt supply over 80 meters with 0.0012 ohms per meter. The drop is 1.73 times 50 times 0.0012 times 80, which gives about 8.3 volts. That equals roughly 2.1 percent of the line voltage. 

Unbalanced loads can push more current through the neutral and alter the result. A three-phase circuit with a neutral current needs a check on the neutral conductor as well. The simple formula assumes balanced loading and a conductor resistance that stays nearly constant. 

## Cable sizing with the percent result 

Voltage drop calculation for cable sizing turns a percent result into a decision about wire cross-section. Each circuit has a limit it must stay under, and the limit depends on the load, the standard in use and the supply voltage. A conductor that passes the voltage drop check may still need a larger size for heat or short-circuit duty. 

Wire cross-section sizing works by trial: pick a size, look up its resistance per length, and run the calculation. If the percent drop exceeds the target, move up one size and repeat. Shortening the cable length or reducing current is another way to bring the result down. 

The voltage drop calculation for cable must start from a real route length, not a straight-line distance. Extra cable for routing, terminations and slack adds to the total. Record the current, voltage, length and conductor data together so the estimate can be checked later. 

## Voltage drop calculation for a car and car audio 

Voltage drop calculation for a car deals with a low-voltage direct current supply that is sensitive to long cable runs. A car audio amplifier can draw large currents, and the feed from the battery to the amplifier adds resistance. Voltage drop calculation for car audio therefore uses the DC formula with the round-trip length. 

The supply voltage in a vehicle is around 12 volts nominal, so a drop of one volt is a large share of the total. A light cable in a long amplifier feed may starve the equipment at high demand. Choosing a thicker conductor or shortening the path lowers the calculated drop. 

Vehicle circuits carry short-circuit risks from a high-current battery feed. Fusing the run near the battery is a separate safety measure for the installer. A voltage drop calculator for car audio only handles the arithmetic, not the protection design. 

## DC, fire alarm and spreadsheets 

Voltage drop calculation formula for DC cables uses current times loop resistance with no reactance term. A fire alarm circuit often runs at a low supply voltage and feeds devices at the far end of a loop. Voltage drop calculation formula for fire alarm system work must reflect the supply voltage and the current each device draws. 

Fire alarm circuits often need the voltage at the last device to stay above the device minimum under alarm load. The load is not always constant along the run, so the drop is summed in stages. A qualified designer should confirm the result against the equipment data and the applicable code. 

An Excel voltage drop sheet is a handy way to repeat the arithmetic for many circuits. A voltage drop calculation formula Excel sheet stores current, length and resistance per length in cells, then returns volts and percent. The sheet is only as sound as the resistance values typed into it. 

## NEC guidance and circuit limits 

NEC voltage drop guidance treats the percent limit as a recommendation for branch circuits and feeders rather than a strict rule. The exact wording belongs to the code edition in force where the work happens. The calculated percent voltage drop is compared with that guidance before a cable size is fixed. 

Circuit voltage drop limits vary with the load type and the standard being followed. Equipment with motors or sensitive electronics may need a lower percent than the guidance figure. A designer should confirm the limit with the authority that governs the installation. 

Voltage drop calculations explained in a code context always cite the supply voltage and the assumed load current. A result without those inputs cannot be judged. Keep the inputs visible in any estimate or drawing note. 

## Voltage drop questions answered 

### How is voltage drop calculated? 

Voltage drop is calculated by multiplying current by conductor resistance over the run length, then applying a circuit factor. Resistance per length comes from the cable data, and the length covers the whole path. The result is often converted to a percentage of the supply voltage. 

### What is the voltage drop formula for single phase? 

The single-phase voltage drop formula is two times current times resistance per length times cable length. The factor of two accounts for the outgoing and return conductors. Dividing the drop by the supply voltage gives the percent voltage drop. 

### What is the voltage drop calculation for 3 phase? 

The three-phase calculation uses 1.73 times current times resistance per length times cable length. The square root of three reflects the phase relationship in a balanced three-phase circuit. Unbalanced loads may need a separate neutral check. 

### Can I get the voltage drop calculation formula as a PDF? 

A PDF of the formula is useful only if it lists the circuit type and the resistance basis. The same arithmetic fits on a single page with the single-phase, three-phase and DC versions. Check that any downloaded sheet matches the cable data you actually use. 

### How does voltage drop affect cable sizing? 

Voltage drop affects cable sizing by ruling out conductors that lose too many volts over the run. You recalculate with the next larger cross-section until the percent drop meets the target. Ampacity and short-circuit duty still decide the final size. 

### Is voltage drop calculation for car audio different from house wiring? 

Car audio voltage drop uses the direct current formula on a low supply voltage close to 12 volts. Large amplifier currents make the cable length and cross-section matter a great deal. House wiring uses alternating current and follows a different code framework.