  1. Why a pre-scan comes first
  2. Static and dynamic methods
  3. Alignment and scan tool routine
  4. Questions about ADAS calibration steps
  5. What does the ADAS calibration process involve?
  6. Is wheel alignment required before calibration?
  7. What is the difference between static and dynamic calibration?
  8. Why does the procedure need a pre-scan and post-scan?

An ADAS calibration procedure is the ordered set of steps a technician follows to aim and verify advanced driver assistance systems after glass, bumper, suspension or sensor work. The process starts with a pre-scan and a check of the vehicle, then moves to target board setup or a road test, depending on what the manufacturer requires. A post-scan closes the job and records whether the systems accept the new aiming.

Why a pre-scan comes first

A pre-scan reads every module on the vehicle before any physical work begins and stores the fault codes for the estimate file. The scan shows whether a sensor already reports a problem that calibration cannot fix. OEM calibration requirements are then checked against the vehicle identification number to confirm the exact procedure. Skipping this step can mean paying for a calibration that a failed part will reject.

Static and dynamic methods

Static calibration parks the vehicle at a measured distance from target boards placed at set heights and angles. Dynamic calibration instead has a technician drive the vehicle under stated conditions so the system can learn its surroundings. The manufacturer decides which method applies and whether both are needed. Target board setup demands a level floor, controlled lighting and clear space around the vehicle.

Alignment and scan tool routine

Wheel alignment is a prerequisite for many calibrations because a sensor aims relative to the chassis and the road. A scan tool calibration routine guides the technician through each step and reports whether the module accepts the result. The post-scan then confirms that the system is live and free of codes. Any rejected step is repeated before the vehicle is returned.

Questions about ADAS calibration steps

What does the ADAS calibration process involve?

The ADAS calibration process moves through a pre-scan, a vehicle and alignment check, the aiming step and a post-scan. Each stage is recorded so the estimate shows what was done and why. The vehicle maker sets the order and the conditions for each stage.

Is wheel alignment required before calibration?

Yes, wheel alignment is a prerequisite for many ADAS calibrations because the sensors aim relative to the chassis. A bent or misaligned suspension changes the angle a camera or radar sees the road. The technician confirms alignment before target boards are placed.

What is the difference between static and dynamic calibration?

Static calibration uses target boards set at fixed positions around a parked vehicle. Dynamic calibration uses a drive cycle so the system learns from real surroundings. The manufacturer states which method the vehicle needs and whether both apply.

Why does the procedure need a pre-scan and post-scan?

The pre-scan records existing fault codes before work starts and protects both the driver and the shop. The post-scan confirms the calibrated system is active and clear of codes. Together the two scans show the calibration was accepted by the vehicle.