# ADAS Calibration Procedure and Process Steps

Learn how an ADAS calibration procedure works, from pre-scan and alignment checks to static or dynamic calibration and the post-scan that confirms the result.

An ADAS calibration procedure is the ordered set of steps a technician follows to aim and verify advanced driver assistance systems after glass, bumper, suspension or sensor work. The process starts with a pre-scan and a check of the vehicle, then moves to target board setup or a road test, depending on what the manufacturer requires. A post-scan closes the job and records whether the systems accept the new aiming. 

## Why a pre-scan comes first 

A pre-scan reads every module on the vehicle before any physical work begins and stores the fault codes for the estimate file. The scan shows whether a sensor already reports a problem that calibration cannot fix. OEM calibration requirements are then checked against the vehicle identification number to confirm the exact procedure. Skipping this step can mean paying for a calibration that a failed part will reject. 

## Static and dynamic methods 

Static calibration parks the vehicle at a measured distance from target boards placed at set heights and angles. Dynamic calibration instead has a technician drive the vehicle under stated conditions so the system can learn its surroundings. The manufacturer decides which method applies and whether both are needed. Target board setup demands a level floor, controlled lighting and clear space around the vehicle. 

## Alignment and scan tool routine 

Wheel alignment is a prerequisite for many calibrations because a sensor aims relative to the chassis and the road. A scan tool calibration routine guides the technician through each step and reports whether the module accepts the result. The post-scan then confirms that the system is live and free of codes. Any rejected step is repeated before the vehicle is returned. 

## Questions about ADAS calibration steps 

### What does the ADAS calibration process involve? 

The ADAS calibration process moves through a pre-scan, a vehicle and alignment check, the aiming step and a post-scan. Each stage is recorded so the estimate shows what was done and why. The vehicle maker sets the order and the conditions for each stage. 

### Is wheel alignment required before calibration? 

Yes, wheel alignment is a prerequisite for many ADAS calibrations because the sensors aim relative to the chassis. A bent or misaligned suspension changes the angle a camera or radar sees the road. The technician confirms alignment before target boards are placed. 

### What is the difference between static and dynamic calibration? 

Static calibration uses target boards set at fixed positions around a parked vehicle. Dynamic calibration uses a drive cycle so the system learns from real surroundings. The manufacturer states which method the vehicle needs and whether both apply. 

### Why does the procedure need a pre-scan and post-scan? 

The pre-scan records existing fault codes before work starts and protects both the driver and the shop. The post-scan confirms the calibrated system is active and clear of codes. Together the two scans show the calibration was accepted by the vehicle.